Coordinate system & sign conventions
Every number EduBeam shows has a sign. This page sets out what positive means for coordinates, loads, displacements, internal forces, end forces and reactions, so you can compare the app with your own calculations. Most results that look wrong turn out to be a sign convention.
| Quantity | Positive |
|---|---|
x, Dx, Fx | to the right |
z, Dz, Fz | down |
Ry, My | counter-clockwise on screen |
| tension | |
| turns a short piece of the member clockwise | |
| sagging: tension in the bottom fibres, on the side of the dashed line | |
| Reactions | the force the support puts on the structure, signed like a load |
Global axes
The model lies in the x–z plane:
- x is horizontal, positive to the right.
- z is vertical, positive down.
- y points out of the screen, toward you, which makes the system right-handed. Rotations and moments are about y, so counter-clockwise is positive.
The axis cross in the corner of the canvas shows x in red and z in green. Because z points down, a node at the top of a 3 m column standing at Z = 0 has Z = −3. Angles, such as the angle of an inclined support, are measured from x toward z, which is clockwise on screen.
If you prefer y up, switch the display convention: the model stays the same, only the numbers you read and type change.
Degrees of freedom
Each node has three degrees of freedom (DOFs):
| DOF | Meaning | Positive | Unit |
|---|---|---|---|
Dx | horizontal displacement | to the right | m |
Dz | vertical displacement | down | m |
Ry | rotation | counter-clockwise | rad |
The same signs apply to prescribed displacements, to the Nodal results table and to the values shown when you point at a node.
Loads
Loads are positive along the positive axes. Fx, Fz and My are the components of a nodal or concentrated load, fx and fz those of a uniform load, and f₁x, f₂x, f₁z, f₂z those of a trapezoidal load at the element's start and end.
| Load | Positive direction |
|---|---|
Fx, fx, f₁x, f₂x | +x, to the right; along the element's local x when LCS is ticked |
Fz, fz, f₁z, f₂z | +z, down; along the element's local z when LCS is ticked |
My | counter-clockwise |
ΔTc | heating of the member's axis, which lengthens it |
ΔTb − ΔTt | bottom fibres warmer than the top ones |
So gravity is a positive fz, and wind pushing a left-hand column to the right is a positive fx. A line load always acts per metre of the member's own length, also when it is given in global axes on an inclined member. The Loads page shows how to enter each type.
Element local axes
Each element has its own axes:
- local x runs from the element's start node to its end node;
- local z is local x turned 90° clockwise on screen, the same turn that takes global x to global z. Walking from the start node to the end node, local z is on your right.
| Element drawn | Local z points |
|---|---|
| left to right | down: local and global axes coincide |
| right to left | up |
| bottom to top | right |
| top to bottom | left |
The element's direction is its angle , measured from global x toward global z (clockwise on screen). The transformation matrix turns end displacements between the two systems with and .
In the viewer, a dashed line along each element marks its local +z side: its bottom fibres. Element loads with LCS ticked, the position of a concentrated load and the end forces all follow the local axes. To turn an element round, use Swap nodes in the Elements table (see element direction).
Internal forces
Cut a member at a distance from its start node. On the face of the part before the cut, whose outward normal points along local +x, the internal forces are positive when they point along local +x, along local +z and counter-clockwise. On the other face they act the opposite way.
In words:
| Quantity | Positive means |
|---|---|
| tension | |
| it turns a short piece of the member clockwise: for a member drawn left to right, up on the piece's left face and down on its right face | |
| sagging: tension in the bottom fibres, on the dashed side |
With and the line load in local axes, they obey
At a concentrated load , or (in local axes) they jump by , and : a force along local +z lowers , and a counter-clockwise moment lowers .
A simply supported beam under gravity load therefore has a positive moment, a positive shear force at its left support and a negative one at its right support. The beam below is also pulled at the roller, so its normal force is positive.
A cantilever turns the moment round: it hogs. A push along its axis compresses it.
In a frame, the bottom of each member is its local +z side, so the order in which you draw a column decides which of its sides is the bottom. This frame is drawn A → B → C → D, which puts local z of every member on the inside: a positive moment means tension on the inside of the frame, and the negative corner moments mean tension on the outside.
The diagrams are drawn as most European courses draw them: on the tension side, and positive on the side away from the dashed line. Settings → Viewer settings → Internal force diagrams can put on the compression side and or on the dashed side. That changes the drawing, never the values: read the sign from the label, not from the side.
End forces (Element results table)
The Element results table lists six end forces per element, in its local axes:
| Column | Acts on the element at | Positive along |
|---|---|---|
X12, Z12, M12 | its start node | local +x, local +z, counter-clockwise |
X21, Z21, M21 | its end node | local +x, local +z, counter-clockwise |
They are the forces the nodes exert on the element: its stiffness matrix times its end displacements, plus the forces that would hold its element loads if both ends were clamped,
where are the element's end displacements in local axes and the equivalent nodal loads of its element loads.
End forces follow the axes, not the –– convention, so at the start node their signs are reversed:
For the simply supported beam above: X12 = −20 kN and X21 = +20 kN (tension), Z12 = Z21 = −30 kN (both supports push up, which is −z), and M12 = M21 = 0.
At every node, the end forces of the elements meeting there, turned into global axes, add up to the nodal load plus the reaction. That makes a quick equilibrium check of a joint.
Reactions
A reaction is the force or moment a support exerts on the structure, one for each restrained DOF. It is signed like a load: positive along +x, along +z (down) and counter-clockwise. A support carrying gravity load therefore has a negative Rz.
Reactions are in global axes, or in the node's own axes when the node has a Nodal LCS angle (an inclined support). In the viewer each reaction is an arrow pointing the way the support pushes, labelled with its magnitude. The signed values are in the CSV export, as Rx, Rz and My.
Y-up axes
Settings → Language & Locale → Coordinate system → x right, y up switches everything you type and read to the textbook system: x to the right, y up and z toward you. The model, saved files and drawings stay exactly the same; only the numbers and the letters change:
| Quantity | x right, z down (default) | x right, y up |
|---|---|---|
| Vertical coordinate | Z | Y, opposite sign |
| Vertical loads, displacements, reactions, end forces | Fz, fz, Dz, Rz, Z12… | Fy, fy, Dy, Ry, Y12…, opposite sign |
| Rotations and moments | Ry, My | Rz, Mz, same sign (counter-clockwise positive) |
| Support angle | measured clockwise | measured counter-clockwise, opposite sign |
| Internal forces | , , | the same, with the same signs, drawn the same way |
So in y-up, gravity is a negative fy, and the top of a 3 m column has Y = 3.
Units
The solver works in SI throughout: m, N, Pa, rad, and K for temperature changes. The display units in Units & settings only change what you type and read, never the model.